IC Bovino Quanti

Quantifies the presence of cow’s milk in just a few minutes. Any operator will be able to analyse milk wherever it is necessary, and the results will be available in real time, uploaded on to the cloud, a mobile device or on location.

 

Want to check that your sheep’s milk or goat’s milk isn’t contaminated with cow’s milk?
Want to know if the milk mixture is below the official limit?
Need to verify that your cheese is pure sheep or goat cheese?
Do you want to check the milk mixture before it will modify the organoleptic characteristics of your product?

 

HOW DOES IT HELP YOU?

 

The IC Bovino Quanti test helps you to easily quantify the presence of cow’s milk in sheep’s or goat’s milk upon arrival at the plant or before the production. You can also carry out checks during milk collection, on the farm or in the truck.
Check the correct cleanliness of tanks and installations to avoid cross-contamination. Just mix a drop of milk with a few drops of the analysis solution and dip the test strip. Thanks to the integration of the IC test on the Test4all platform you will be able to read the strip automatically, receive and store the results on your mobile or tablet in real time and ensure its full traceability.

MATRIX
COW MILK

APLICACIONES Y USUARIOS
TANK

TRUCK

TANKER

ASSAY PROCEDURE

1. Mix:

20μL of sample and 200μL solution dilution.

2. Incubation:

10 min. at room temp.

3. Results:

On the APP, mail or test4all.es platform

Video name

1. Dilución de la muestra:

Aplicar muestra/patrón. Incubación.

2. Conjugado:

Incubación

3. Results:

Check the result at the app.

TEST PRINCIPLE

Immunochromatographic test based on the detection of bovine (IgG) immunoglobulins G by specific antibodies. Each batch is adapted for quantification the milk mixture with the IRIS reader.

TECHNICAL DATA

  • Range of detection: 0,1% – 100%
  • Range of quantification: 0,25 – 2,0%
  • Assay time: 10 minutes.
  • Results: visual and objective reading with the IRIS reader.
  • Connectivity: in real time (Bluetooth/4G).

 

Validations:

Internal validation following the AOAC and Eurachem guidelines:

Appendix F: Guidelines for Standard Method Performance Requirements. Official Methods of Analysis (2016), AOAC INTERNATIONAL, Rockville, MD, USA (www.eoma.aoac.org/app_f.pdf) This reference is common for qualitative and quantitative tests.

EURACHEM, 1998. The Fitness for Purpose of Analytical Methods: A Lab-oratory Guide to Method Validation and Related Topics. EURACHEM.

References AOAC (Association of Official Analytical Chemists), 2012. Guidance for Standard Methods Performance Requirements. AOAC. Bansal, B., Chen, X.D., 2006.